3 Phase Control, 2 Leg Break 25A/Leg Burst Fire SCR Assembly
PART NUMBER
INPUT
RANGE
ASSEMBLY LOAD CURRENT
(AMPS AC)
LINE
VOLTAGE
PEAK VOLTAGE
RELAY RATING
4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer
1200V Peak
.1A/Leg-25A/Leg Max @
40C Ambient
48-660Vac
25A/Leg
4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer
.1A/Leg-25A/Leg Max @
40C Ambient
48-660Vac
1200V Peak
25A/Leg
3 Phase Control, 2 Leg Break 40A/Leg Burst Fire SCR Assembly
PART NUMBER
INPUT
RANGE
ASSEMBLY LOAD CURRENT
(AMPS AC)
LINE
VOLTAGE
PEAK VOLTAGE
RELAY RATING
4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer
1200V Peak
.1A/Leg-40A/Leg Max @40C Ambient
48-660Vac
40A/Leg
4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer
.1A/Leg-40A/Leg Max @40C Ambient
48-660Vac
1200V Peak
40A/Leg
3 Phase Control, 2 Leg Break 50A/Leg Burst Fire SCR Assembly
PART NUMBER
INPUT
RANGE
ASSEMBLY LOAD CURRENT
(AMPS AC)
LINE
VOLTAGE
PEAK VOLTAGE
RELAY RATING
4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer
1200V Peak
.1A/Leg-50A/Leg Max @40C Ambient
48-660Vac
50A/Leg
4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer
.1A/Leg-50A/Leg Max @40C Ambient
48-660Vac
1200V Peak
50A/Leg
3 Phase Control, 2 Leg Break 75A/Leg Burst Fire SCR Assembly
PART NUMBER
INPUT
RANGE
ASSEMBLY LOAD CURRENT
(AMPS AC)
LINE
VOLTAGE
PEAK VOLTAGE
RELAY RATING
4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer
1200V Peak
.1A/Leg-75A/Leg Max @40C Ambient
48-660Vac
75A/Leg
3 Phase Control, 2 Leg Break 25A/Leg SSR Assembly
PART NUMBER
INPUT
RANGE
ASSEMBLY LOAD CURRENT
(AMPS AC)
LINE
VOLTAGE
PEAK VOLTAGE
RELAY RATING
3-32Vdc
1200V Peak
.1A/Leg-25A/Leg Max @
40C Ambient
48-660Vac
25A/Leg
3 Phase Control, 2 Leg Break 40A/Leg SSR Assembly
PART NUMBER
INPUT
RANGE
ASSEMBLY LOAD CURRENT
(AMPS AC)
LINE
VOLTAGE
PEAK VOLTAGE
RELAY RATING
3-32Vdc
1200V Peak
.1A/Leg-40A/Leg Max @
40C Ambient
48-660Vac
40A/Leg
3 Phase Control, 2 Leg Break 50A/Leg SSR Assembly
PART NUMBER
INPUT
RANGE
ASSEMBLY LOAD CURRENT
(AMPS AC)
LINE
VOLTAGE
PEAK VOLTAGE
RELAY RATING
3-32Vdc
1200V Peak
.1A/Leg-50A/Leg Max @
40C Ambient
48-660Vac
50A/Leg
Address
Anacon Power & Controls
100 Powder Mill Rd. Suite 162
Acton, MA 01720
Phone
TEL: 800-466-9080
TEL: 978-287-0715