top of page

Duct Heater Controls

   Duct Heaters require unique controls for efficient operation. Controlling multiple heaters and varying control outputs can be easily accomplished when the proper complement of control products are employed.

Anacon Power manufactures low-cost Burst Fire SCR Controllers for Loads up to 100 AMPs in Single or 2/Leg Break of three Phase Line versions. We also supply the Solid State Relays and heat sink products that meet just about any thermal situation.

All of our products are competitively priced and are ROHS compliant. Check out all of the control products offered by

Anacon Power & Controls.

 

Give our experts a call and let us show you how we can be your 21st century source for controls. 1-800-466-9080

or send us an email.

  • Duct/Panel Mount Dual Burst Fire SCR Controllers

  •  Panel Mount Dual Burst Fire SCR Assemblies

    • 75AMP

    • 100AMP (Coming Soon)

  • Duct/Panel Mount Dual SSR Assemblies

  • Panel Mount Dual SSR Assemblies

    • 75AMP (Coming Soon)

    • 100AMP (Coming Soon)

3 Phase Control, 2 Leg Break 25A/Leg Burst Fire SCR Assembly

PART NUMBER

INPUT

RANGE

ASSEMBLY LOAD CURRENT

(AMPS AC)

LINE

VOLTAGE

PEAK VOLTAGE

RELAY RATING

4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer

1200V Peak

.1A/Leg-25A/Leg Max @
40C Ambient

48-660Vac

25A/Leg

4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer

.1A/Leg-25A/Leg Max @
40C Ambient

48-660Vac

1200V Peak

25A/Leg

3 Phase Control, 2 Leg Break 40A/Leg Burst Fire SCR Assembly

PART NUMBER

INPUT

RANGE

ASSEMBLY LOAD CURRENT

(AMPS AC)

LINE

VOLTAGE

PEAK VOLTAGE

RELAY RATING

4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer

1200V Peak

.1A/Leg-40A/Leg Max @40C Ambient

48-660Vac

40A/Leg

4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer

.1A/Leg-40A/Leg Max @40C Ambient

48-660Vac

1200V Peak

40A/Leg

3 Phase Control, 2 Leg Break 50A/Leg Burst Fire SCR Assembly

PART NUMBER

INPUT

RANGE

ASSEMBLY LOAD CURRENT

(AMPS AC)

LINE

VOLTAGE

PEAK VOLTAGE

RELAY RATING

4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer

1200V Peak

.1A/Leg-50A/Leg Max @40C Ambient

48-660Vac

50A/Leg

4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer

.1A/Leg-50A/Leg Max @40C Ambient

48-660Vac

1200V Peak

50A/Leg

3 Phase Control, 2 Leg Break 75A/Leg Burst Fire SCR Assembly

PART NUMBER

INPUT

RANGE

ASSEMBLY LOAD CURRENT

(AMPS AC)

LINE

VOLTAGE

PEAK VOLTAGE

RELAY RATING

4-20mA, 0-10Vdc, 0-5Vdc,
0-135Ω , Potentiometer

1200V Peak

.1A/Leg-75A/Leg Max @40C Ambient

48-660Vac

75A/Leg

3 Phase Control, 2 Leg Break 25A/Leg SSR Assembly

PART NUMBER

INPUT

RANGE

ASSEMBLY LOAD CURRENT

(AMPS AC)

LINE

VOLTAGE

PEAK VOLTAGE

RELAY RATING

3-32Vdc

1200V Peak

.1A/Leg-25A/Leg Max @
40C Ambient

48-660Vac

25A/Leg

3 Phase Control, 2 Leg Break 40A/Leg SSR Assembly

PART NUMBER

INPUT

RANGE

ASSEMBLY LOAD CURRENT

(AMPS AC)

LINE

VOLTAGE

PEAK VOLTAGE

RELAY RATING

3-32Vdc

1200V Peak

.1A/Leg-40A/Leg Max @
40C Ambient

48-660Vac

40A/Leg

3 Phase Control, 2 Leg Break 50A/Leg SSR Assembly

PART NUMBER

INPUT

RANGE

ASSEMBLY LOAD CURRENT

(AMPS AC)

LINE

VOLTAGE

PEAK VOLTAGE

RELAY RATING

3-32Vdc

1200V Peak

.1A/Leg-50A/Leg Max @
40C Ambient

48-660Vac

50A/Leg

Address

Anacon Power & Controls

100 Powder Mill Rd. Suite 162

Acton, MA 01720

Phone

TEL: 800-466-9080
TEL: 978-287-0715

Email

bottom of page